Products

The Probe of Coating Thickness Gauge

 F-use magnetic probe, based on measurable magnetic metal (such as steel, iron, steel alloys and hard-magnetic, etc.) on non-magnetic coating thickness (such as zinc, aluminum, chromium, copper, rubber, paint, etc.). 
N-type probe use of eddy current way, measurable magnetic non-ferrous metal matrix (such as copper, aluminum, zinc, tin, etc.) and non-conductive, Austenitic stainless steel cover the thickness (such as: rubber, paints, plastics, anodizing film ). 
F / N-probe (except N400) gage with the times and can be used, other brands gage would need change.

The Probe of Coating Thickness Gauge

technical parameters

    F-use magnetic probe, based on measurable magnetic metal (such as steel, iron, steel alloys and hard-magnetic, etc.) on non-magnetic coating thickness (such as zinc, aluminum, chromium, copper, rubber, paint, etc.). 
N-type probe use of eddy current way, measurable magnetic non-ferrous metal matrix (such as copper, aluminum, zinc, tin, etc.) and non-conductive, Austenitic stainless steel cover the thickness (such as: rubber, paints, plastics, anodizing film ). 
F / N-probe (except N400) gage with the times and can be used, other brands gage would need change.

F1 probe

 

F1-use magnetic probe, based on measurable magnetic metal (such as steel, iron, steel 
alloys and hard-magnetic, etc.) on non-magnetic coating thickness (such as zinc, 
aluminum, chromium, copper, rubber, paint, etc.). 
Measuring principle: magnetic 
Measuring range :0-1250 um 
Measurement accuracy: one point calibration: ± (3% H +1), two point calibration: ± (1% H +1) 
Low-limit resolution: 0.1 
Minimum radius of curvature (convex): 1.5 
The smallest diameter: f7 
Matrix critical thickness: 0.5

 

F10 probe:

F10-use magnetic probe, based on measurable magnetic metal (such as steel, iron, 
steel alloys and hard-magnetic, etc.) on non-magnetic coating thickness (such as zinc, 
aluminum, chromium, copper, rubber, paint, etc.). 
Measuring principle: magnetic 
Range: 0 – 10mm 
Measurement accuracy: one point calibration: ± (3% H +10) ;two point calibration: ± (1% H +10) 
Low-limit resolution: 1 
Minimum radius of curvature (convex): 10 
The smallest diameter: f40 
Matrix critical thickness: 2 
Can be allocated CTG3100/CTG4100 / TIME 260

 

 

F1/90 probe


F1/90 of the probe using magnetic method, based on measurable magnetic metal 
(such as steel, iron, steel alloys and hard-magnetic, etc.) on non-magnetic coating 
thickness (such as zinc, aluminum, chromium, copper, rubber, paint, etc.). 
Measuring principle: magnetic 
Measuring range :0-1250 um 
Measurement accuracy: one point calibration: ± (3% H +1)
two point calibration: ± (1% H +1) 
Low-limit resolution: 0.1 
Minimum radius of curvature (convex): straight 
The smallest diameter: f7 
Matrix critical thickness: 0.5 
Can be allocated CTG3100/CTG4100 / time 260

 

F400 probe

F400-use magnetic probe, based on measurable magnetic metal (such as steel, iron, 
steel alloys and hard-magnetic, etc.) on non-magnetic coating thickness (such as zinc, 
aluminum, chromium, copper, rubber, paint, etc.). 
Measuring principle: magnetic 
Measuring range :0-400 um 
Measurement accuracy: one point calibration: ± (3% H +0.7) two point calibration: ± (1% H +1) 
Low-limit resolution: 0.1 
Minimum radius of curvature (convex): 1 
The smallest diameter: f3 
Matrix critical thickness: 0.2 
Can be allocated CTG3100. / CTG4100 / TIME 260

 

N1 probe

 

N1 type eddy current probe the eddy current way, measurable magnetic non-ferrous 
metal matrix (such as copper, aluminum, zinc, tin, etc.) and non-conductive, 
Austenitic stainless steel cover the thickness (such as: rubber, paints, plastics, 
anodizing film ) 
Measuring principle: Eddy 
Measuring range :0-1250 um

Measurement accuracy (um): one point calibration ± (3% H +1.5) ;two point 
calibration: ± (1% H +1.5) 
Low-limit resolution: 0.1 
Minimum radius of curvature (convex): 3 
The smallest diameter: f5
Matrix critical thickness: 0.3

 

N400 probe

N400-eddy current probe by the eddy current way, measurable magnetic non-ferrous 
metal matrix (such as copper, aluminum, zinc, tin, etc.) and non-conductive, 
Austenitic stainless steel cover the thickness (such as: rubber, paints, plastics, 
anodizing film ) 
Measuring principle: Eddy 
Measuring range :0-400 um

Measurement accuracy (um): one point calibration: ± (3% H +1) 
two t point calibration: ± (1% H +1) 
Low-limit resolution: 0.1 
Minimum radius of curvature (convex): 1.5 
The smallest diameter: f4 
Matrix critical thickness: 0.3